Technical Data:
\n \n| Basic info | \nCelsius | \nFahrenheit | \n
| Temperature range | \n-30℃~500℃ | \n-22℉ ~ 932℉ | \n
 Â
\n \n| Accuracy | \nGeometric Correction | \n||
| < 400℃ | \n>400℃ | \n||
| Response Time | \n95% reading | \n<500ms | \n<300ms | \n
| Ambient \n \nTemperature \n \n23℃±2℃ | \n≥0℃ / ≥32℉ | \n±1.5℃ or reading±5% \n \n(±3℉ or reading±5%) \n \ntake large value) | \n±1℃ or reading±5% \n \n(±2℉ or reading±5%) \n \ntake large value | \n
| <-10℃ /<14℉) | \n±3℃ / ±6℉ | \n||
| -10℃~0℃ / 14℉~32℉ | \n±2℃ / ±4℉ | \n||
\nSpecial Function:
\n \n| Protection level (IP) | \nAccording to IEC 60529, the protection level is IP54 | \n
| Drop test | \n3 meters | \n
| Vibrationand Shock protecion | \nIEC 60068-2-6,2.5g, 10 to 200Hz, IEC 60068-2-27, 50g | \n
| Laser safety | \n11mEN 61325-1:2006 | \n
| Measuring distance | \nD:S=12:1 (measuring distance to target object) | \n
| Measuring condition | \nVacuum medium | \n
| Spectral response | \n8 to 14 Micron | \n
| Emissivity | \n0.10 to 1.00Â adjustable | \n
| Temperature coeffcient | \n±0.1℃/℉ or ±0.1% of reading, whichever is larger | \n
| Optical resolution | \n12:1 (when energy is 95% calculate ) | \n
| Display resolution | \n 0.1℃ / 0.2℉ | \n
| Repeatability (reading %) | \nReading ±0.8% or 1.0℃/2, take the larger value | \n
| Auto power off time | \napprox. 6s | \n
| Sampling rate | \n≤ 0.5s | \n
| Backlight display function | \n√ | \n
| Low battery indication | \n√ | \n
| Data hold function | \n√ | \n
| Max./Min./AVG./DIF. HOLD function | \n√ | \n
| High/Lowtemperature Alarm function | \n√ | \n
| Zero offset adjustment | \n√ | \n
| Unit Symbol display | \n√ | \n
| Max. display | \n3digits | \n
| Power supply | \n6F22, 9VÂ (extra heavy battery) | \n
| Battery life | \n10 hours when the laser and backlight are on. | \n
| Power consumption | \n≤50mW | \n
| Meter weight | \n177g (with battery) | \n
| Meter size | \n95x43x155mm | \n
INSTRUCTIUNI UTILIZARE